Intel S4600LH Server Board Family Firmware 2.03/2.01/1.21/0.23

Manufacturer:

Description

DOWNLOAD NOW

Versions:

- BIOS: R02.03.0003
- ME: 02.01.07.328
- BMC: 01.21.6038
- FRUSDR: 0.23

BIOS R02.03.0003

- This version enhances the protection of certain UEFI variables as described in Intel Security Advisory INTEL-SA-00038

BMC changes in release 01.21.6038

- Fixed: BMC User configuration is corrupted and users cannot be re-created.
- Fixed: The response of getting satellite fw update status is always 01
- Fixed: HSC slots status present sensor showed NA in EWS.
- Fixed: (X) Disk Drive LED - Locating drive is inconsistent in time to illuminate and stop
- Fixed: Hot Plug Fan not changing system status on Fan failure.
- Fixed: EWC Fan sensor readings disappear when filtered and there is a fan failure.
- Fixed: (X) BMC hung after network Scan.
- Fixed: Current power is incorrect on EWS while power down SUT by pressing power button.
- Fixed: Special characters '<>' of FRU info can't be shown in the EWS page.
- Fixed: Recurring temperature alarms on sensor #0x22(SSB).
- Fixed: DIMM Thrm Mrgn sensor shows "unknown" when just plug DIMM in Channel3
- Fixed: [X] Updated Java signitures to support new JAVA requirements.
- Fixed: Get SOL Configuration parameters 5 & 6 should not return invalid response.
- Fixed: EWS is incorrectly decoding ME firmware update SEL events.
- Fixed: BMC channle 1 can not ping succesfully and EWS login fail while using static IPV6 address.
- Fixed: Baseboard IP address can't be assigned when IPv6 address set as auto-configuration.
- Fixed: IP address can't be assigned when IPv6 address set as dynamic.
- Fixed: BMC Hangs during first A/C power up.
- Fixed: CFM calculation failed on PSU removal/insertion.
- Fixed: Enable FPGA logic to preserve PWM registers.
- Fixed: Check in 750AB V8 PSU image per PSU verification team's request
- Fixed: Porting FRU discovery APIs from Grantley where the Auto-Configuration feature requires the operational status of the managed FRUs.
- Fixed: Add the displaying of the PS HW Revison for the PS if update is required or not.

ME changes in release 02.01.07.328

- Fixed: Platform is not able to power on properly after being shut down by NM Policy.
- Fixed: Global platform power consumption reported by NM Statistics in S5 is incorrect.
- Fixed: OOB (out-of-band) stress test by issuing the wrong username may cause connection to be unavailable.
- Fixed: Shutdown action can be interrupted by cold reset when volatile NM policy is in use.

FRUSDR changes in release 0.23

- Changed LC/LNC thresholds for all CPUs to match processor specs.




Intel S4600LH Board Family Firmware Intel S4600LH Board Series Firmware Intel S4600LH UEFI Firmware S4600LH Firmware Intel Server Board