NETGEAR FSM7226P Switch Firmware 10.0.2.35

Manufacturer:

Description

DOWNLOAD NOW

New Features:

- Compliant with California Privacy Law: Force user to change the default password on first login to the device.
- In the web GUI “LAG Configuration” page, replace "Active Ports" field with “Down Ports” for each LAG group to easily spot the offline member port

Bug Fixes:

- Switch randomly restored to factory default settings after reboot.
- Switch management no longer respond if the default gateway becomes unreachable.

Changes and Restrictions:

- If the network is set to DHCP mode on version 10.0.1, and then is upgraded to 10.0.2, the network interface protocol mode changes to ‘none’ and its IP is set to ‘0.0.0.0.’, and DHCP mode is enabled on the management VLAN instead.
- Auto-install is not allowed to apply a configuration file if the startup-config file contains commands related to the network interface, which is not supported on 10.0.2.
- M4100 does not support IPv6 management on the management VLAN.
- If a protected port is configured, routing mode disabled on the VLAN with the protected port.
- When M4100-D12G-POE+ / GSM5212P is powered up through PD ports 1 and 2, and ports 3 - 12 are used as PSE ports, the maximum PoE power budget delivered by ports 3 - 12 will be only 25W.
- If the switch model is a PoE switch, note that the new release comes with a new PoE controller firmware that required a few extra minutes to perform the PoE firmware update. During this time, do not power off the switch. If the update fails, unplug all cables from the ports and power cycle the switch.
- Do not use a USB flash port to perform the firmware update if the switch model is a PoE model.

Upgrade procedure:

1. Save the current configuration data. Normally the firmware will preserve the original configuration in the switch, however, just in case something went wrong during the upgrade, you may want to save a copy of current running configuration. To do so, go to 'Maintenance->Upload' page, and select Text Configuration option and click Apply button to save the configuration file.

2. Download and extract the new firmware to a convenient place such as your desktop.

3. There are two ways to download the new firmware from PC to the switch. One is using TFTP which requires a TFTP server be installed on the PC where the firmware is stored from step #2. The second method is to use web browser for downloading which requires of no TFTP server. If you preferred to use TFTP method, or you're using telnet session to perform firmware upgrade, continue to step #5.

4. To use HTTP method, go to the following web GUI page, and select the location of the new firmware via browse button, then click Apply button to start firmware upgrade. The upgrade will take about 12 minutes. Do not power cycle the switch before the process is complete.
After the Apply button is clicked, the file transfer will start, and followed by writing the new image to the Flash memory. Do not power cycle or reboot the switch before the process is complete and the success message show up as below.
After the successful completion the upgrade, proceed to step #8 to restart the switch.

5. Start a TFTP server on the PC where the new images are stored. If you do not have a TFTP server, you may want to try the following public domain TFTP servers: PumpKIN - http://kin.klever.net/pumpkin/

6. You can use either web interface or CLI interface to perform upgrade using TFTP. To use web interface, just go to file utility page on the web and follow the screen instruction to complete the firmware upgrade. To use CLI, either telnet into the switch or use console port and follow these steps below.

7. On the switch console, type the following command:
a. # copy tftp://<tftp server IP address><image name> system:image
b. It will ask for confirm with input data displayed. Hit enter if all parameters look correct.
c. The download should take a minute or two, after that, the code will be checked for possible corruption, if not, it will report firmware successfully upgraded.
d. Reboot the switch by typing "reload" command or power cycle the switch.

8. To use GUI to restart the switch, go to web page 'Maintenance->Reset' page, Device Reboot table.
Make sure that "All" is selected in 'Reboot Unit No' drop down menu box. If it is shown with some other value like '1', then only unit 1 in the stack will be rebooted, and this may result in stack failure after the stack is rebooted. You may select 'Save prior to reboot' option if you feel there are changes that may not have being saved. Click 'APPLY' button to start the reboot process.

9. After the switch is restarted, type the following CLI command to verify the version is correct. # show hardware
Or go to GUI System main page to confirm the switch firmware is the one downloaded.

10. Verify the switch running configuration by issuing "show running-config" command. The output should match the configuration file saved on step #1. If there are not, please call NETGEAR customer support on discrepancy. And manually re-apply the missing configuration commands back to the switch.

11. You can now make additional configuration change for another other application need. And be sure to use "save" command to save the configuration after you're done. 

About Switch Firmware:

Given the large variety of models and different methods for upgrading the switch, if you wish to apply this package, we recommend that you read and understand the installation steps before you install a new firmware, even if you are a power user.

Usually the update procedure isn't much of a hassle as manufacturers try to make it as simple as possible; however, there are cases that are exceptions to this rule. First off, go to the system information page of the switch to check that the currently installed version isn't either newer or matching this release.

Applying a new firmware can decrease the security vulnerabilities, enhance overall performance and compatibility, improve various power management functions, resolve different errors, and add support for newly developed technologies and protocols.

It is recommended that you perform this step in a steady power environment such as the one ensured by a UPS unit, and that you don't interrupt the upgrade in any way, because this might cause the switch to malfunction.

That being said, click the download button, get and apply the new version, and check back with our website constantly to stay up to speed with the latest releases.

NETGEAR FSM7226P Firmware NETGEAR M4100-26-POE Switch Firmware NETGEAR M4100-26-POE Firmware FSM7226P Firmware NETGEAR Switch

  CATEGORY:
Router / Switch / AP
  COMPATIBLE WITH:
OS Independent
  file size:
11.5 MB
  filename:
GSM_FSM_52_7200_V10.0.2.35.zip