Firmware - 4.230.31-3587
SCGCQ00625524 - When we attempt to retrieve iMR Thunderbolt controller firmware logs using an application, we see some lines that are wrapped without starting on a new line.
SCGCQ00695317 - Serial prints getting jumbled up due to print message inside spurious interrupt handler.
SCGCQ00675262 - Data Corruption is taking place on Windows OS installed on top of ESX 5.5 U1 OS.
SCGCQ00665475 - ONFI: To properly handle the OCR case with RESET Status Register.
SCGCQ00677803 - Cache offload failure with pinned cache on R5 VD
SCGCQ00674392 - Updated long term WA for PPC errata number 46
SCGCQ00568080 - Defect Fix for VPD and inquiry callback issues in DISM
SCGCQ00568134 - Patrol read will not start on any VD after a PR is started, suspended and VD is deleted
SCGCQ00569895 - Defect Fix for Command gets retried infinitely times when drive responds with 0B/47/03 always
SCGCQ00572662 - FW failure during read on 3PD R5 with 1000 CME with skip count 2
SCGCQ00574276 - FW breaks if wrong security key is entered
SCGCQ00580162 - Only 1mb crash dump is getting generated of fw fault
SCGCQ00580847 - not enough bs found during double Dip power cycle Test
SCGCQ00586163 - cache restore failure message displayed through cache restore was successful
SCGCQ00588173 - Routines to inject bit error in NF and ecc error in DDR for ONFI
SCGCQ00588185 - Mismatch in LD id and target ID during set/reset boot device
SCGCQ00589365 - on breaking the multipath in loop while drives are spinning up will result in montask
SCGCQ00589728 - FW hangs while creating 64 VDs on the controller with SLES11 SP2
SCGCQ00592996 - While running reconstruction from R1 to 4 drive PRL11 with IO,FW hits to MonTask: line 1270 in file ../../raid/1078dm
SCGCQ00593776 - SMART poll needs to issue log sense with page control set to current/ cummulative value
SCGCQ00602556 - Static analysis tool defects
SCGCQ00602665 - Static analysis tool defect
SCGCQ00602726 - Static Analysis Tool defects
SCGCQ00602855 - Static analysis tool defect
SCGCQ00603306 - static analysis tool defects resolution
SCGCQ00603564 - added support for debug queue
SCGCQ00603779 - Not getting "Clear ldbm badblocks" options on VD
SCGCQ00611275 - FW goes to kill adaptor to handle partial copy of crash_dump
SCGCQ00612927 - Montask in divert.c seen when injecting 64K consecutive errors on R0 VD, Patrol Read running in background.
SCGCQ00614455 - Static analysis tool defects
SCGCQ00625843 - PR Progress event is not generated for 1TB/3TB SATA drive
SCGCQ00634578 - Defect fix for kernel panic with iMR Fury with Freebsd driver
SCGCQ00636748 - Running Storcli /C0/CV show or (show all) starts a relearn on supercap issue
SCGCQ00451219 - Defect Fix for Online DIF drives are getting punctured after PI enabled R5 VDs are offlined with pinned cache
SCGCQ00574071 - md5sum mismatch seen on a copied file from R5 VD with CME
SCGCQ00574277 - Power removal of enclosure FW hits to MonTask: line 4056 in file ../../bbu/onfiBBM.c
SCGCQ00586190 - Fix GNU make file compilation
SCGCQ00586341 - Crash Dump Error Handling
SCGCQ00605227 - When OS on VD ,after collecting crash dump file system becomes readable
SCGCQ00606571 - Physical drives go to power save mode just after restarting the server
SCGCQ00610881 - storcli and CtrlR still show new PD information as 4K sector after replacing a 4K sector drive with a 512 sector drive
SCGCQ00630075 - Unexpected power state change
SCGCQ00631492 - Media error on Last sector of stripe isn't added to LDBBM list
SCGCQ00524842 - CME logic using overlaid fields in c->rec
SCGCQ00568655 - defect fix for Compilation issue
SCGCQ00575006 - Too many unexpected sense AEN raised by CC during CME recovery on R5
SCGCQ00593295 - Not able import foreign configuration immediately after breaking the mirror.
SCGCQ00602561 - Static Analysis Tool defects
SCGCQ00563498 - FW should not try to boot iMR mode without informing host if ECC error happens when OS is running.
SCGCQ00577680 - spin up tracker dequeue is not handled for case in which TUR error happens even after MAX retries
SCGCQ00603086 - Kill adapter is seen while performing CME recovery during Write operation.
SCGCQ00466289 - PDs more than 32 which has configuration, is reporting as JBODs after importing from MR to IMR
SCGCQ00546691 - hostCmdSortingWrites is not updated when VD policy changes(WT/WB)
SCGCQ00576138 - The restore successful and unsuccessful prints to be handled properly
SCGCQ00560474 - code review change implemented
SCGCQ00531118 - Changes to support PD IO history
SCGCQ00564339 - Enable break mirror support
SCGCQ00574801 - Implemented Fix to Problem [PDs more than 32 which has configuration, is reporting as JBODs after importing from MR to IMR]
SCGCQ00577793 - Moved divert code from iopath region to save memory
SCGCQ00621767 - Update Ptolemy VPD and GasGauge with COL settings for a OEM
SCGCQ00624326 - Disable sgpioSmpPresenceDetect for OEM
SCGCQ00625006 - Show valid ROC temperature
SCGCQ00625044 - Change SES Green/Amber LED behavior
SCGCQ00567706 - Extended LDBBM table to hold more bad block entries ( SCGCQ00295621); with relevant increase in divert nodes.
SCGCQ00588208 - Adding test routine for the bad block loop test for PR SCGCQ00423195
SCGCQ00563795 - Modify MR fw to eliminate four second window where drive swap is not recognized.
SCGCQ00564166 - Single image support for ONFI
SCGCQ00455360 - Implement CME solution for "Do not allow 3 minute timer to expire forcing driver to kill fw on CME/disk timeout/etc.
SCGCQ00563486 - Make MR to iMR migration generic on TMM fault
SCGCQ00562733 - Support for DIS feature in dual image
SCGCQ00530866 - command storclif /c1 start diag duration=0 causes controller card to montask.
SCGCQ00564367 - BGI operation still running on RAID0 VD even after PI protection disabled
SCGCQ00566951 - LED Blink operation doesn't stop after VD deletion
SCGCQ00579929 - SGPIO functionality is not working when only cable A is connected
SCGCQ00579931 - Potential null pointer dereference
SCGCQ00614997 - Physical drives go to power save mode just after restarting the server
SCGCQ00614998 - Physical drives go to power save mode just after restarting the server
SCGCQ00615001 - Montask in divert.c seen when injecting 64K consecutive errors on R0 VD, Patrol Read running in background.
SCGCQ00617621 - cache restore failure message displayed through cache restore was successful
SCGCQ00620166 - RAID configured on PD been erased with Normal or Thorough will lost after system reboot/reset
SCGCQ00620168 - RAID configured on PD been erased with Normal or Thorough will lost after system reboot/reset
SCGCQ00620169 - RAID configured on PD been erased with Normal or Thorough will lost after system reboot/reset
SCGCQ00621785 - CME handling of Invader
SCGCQ00622709 - storcli and CtrlR still show new PD information as 4K sector after replacing a 4K sector drive with a 512 sector drive
SCGCQ00624531 - Cache policy of Virtual Drives(VD) does not change to Write Through(WT) mode even after detecting a bad supercap.
SCGCQ00631230 - SSD causes system to hang at POST
SCGCQ00631232 - Behavior change when FW hit fault code 0x81 (uncorrectable ECC error)
SCGCQ00631474 - Power removal of enclosure FW hits to MonTask: line 4056 in file ../../bbu/onfiBBM.c
SCGCQ00631478 - Adding 2GB DDR and 4GB Flash combination support for Single Image Write.
SCGCQ00637535 - FW hits MonTask: line 1143 in file ../../raid/pd.c on starting VD erase in standard mode.
SCGCQ00638312 - FW crash while launching Ctrl+R
SCGCQ00640126 - 9240-4i is not getting required memory resources on boot, on Linux it waits 5 minutes, resets the
SCGCQ00640469 - Running Storcli /C0/CV show or (show all) starts a relearn on supercap issue
SCGCQ00640470 - L2/L3 cache error on H330 MM & H330 MB on reboot
SCGCQ00643455 - Defect fix for kernel panic with iMR Fury with Freebsd driver
SCGCQ00643524 - Defect fix for kernel panic with iMR Fury with Freebsd driver
SCGCQ00643526 - 9240-4i is not getting required memory resources on boot, on Linux it waits 5 minutes, resets the
SCGCQ00658583 - Work Around for PPC 476 Errata number 46 in MR Firmware
SCGCQ00658585 - Work Around for PPC 476 Errata number 46 in iMR Firmware
SCGCQ00495877 - disableBatteryWarning should not be reset if changed by user
SCGCQ00552416 - firmware 25.2.0-0013 causes the SEP to not be seen on x4 Equinox
SCGCQ00555332 - Transparent Learn Cycle does not kick off and RSOC (Relative State Of Charge) eventually goes down to 0%.
SCGCQ00559322 - EEprom CRC error is detected when WebBIOS is running
SCGCQ00579928 - AdpDiags does not fail when the SAS link is down
SCGCQ00588880 - HDD resume failed during dimmer switch test method.
SCGCQ00630382 - Add MaintainPdFailHistory clear function
SCGCQ00631340 - Single image support for ONFI
SCGCQ00637536 - FW hits MonTask: line 1143 in file ../../raid/pd.c on starting VD erase in standard mode.
SCGCQ00675820 - Updated long term WA for PPC errata number 46
SCGCQ00504394 - For a particular OEM, size of some 4TB drives is reported as zero
SCGCQ00523966 - Rebuild failed event is not seen when rebuild fails due to LDBBM and SBBM tables getting full (puncturing disabled)
SCGCQ00552446 - Implement I2C Slave Address for Sideband Management
SCGCQ00563282 - OEM hi-temp warning not being displayed
SCGCQ00570249 - OEM SGPIO support not working
SCGCQ00574969 - Retention test failure during stress test
SCGCQ00596686 - cntr-R fails to show correct PD sector size once PD's swapped to same slot 512B PD with 512e PD type
SCGCQ00621783 - Assertion failure (not enough BS found) in double DIP power cycle test case
SCGCQ00646386 - DIS mismatch while running system reboot script with dirty data in DDR
SCGCQ00366011 - FW goes to montask at cache offload.
SCGCQ00498741 - Megamon during Injecting errors to VD with 512e PDs on iMR controller
SCGCQ00526627 - Faulty protocol used for changing the Disk Write Cache Policy
SCGCQ00530868 - "OOB:Got DCMD, but FW is not ready " messages are flooding in tty log during OCR .
SCGCQ00553197 - Prevent overtemp warnings while charging between 45C and 50C
SCGCQ00560388 - adapterOperations.alarmControl is being set to 1 even if controller does not have alarm on board
SCGCQ00567378 - CLI Reporting of TMM VPD
SCGCQ00556598 - megacli reports battery pack is missing on hot insertion
SCGCQ00679766 - MonTask: line 4699 in file ../../raid/ld.c seen on iMR FW during boot to OS with R0 and PRL11 VD
SCGCQ00550612 - Do not print VPD86 errors for BP/expander
SCGCQ00552415 - Modify WCE bit for improved Linux performance
SCGCQ00560393 - When attempting to secure LD during RLM, receive option to secure LD, LD not secured (message incorrect/misleading.)
SCGCQ00558037 - Megamon issue when disabling the drive security on a MR controller with spun down FDE drives.
SCGCQ00560476 - Unable to open "Set Patrol Read Properties" in MSM with 2008-iMR
BIOS - 6.17.04.0
SCGCQ00579962 - Initialize deviceExposure with MAX_INT13DISKS instead of 0xFF
SCGCQ00572939 - Make sure all the make file adheres to the latest binary names.
SCGCQ00559095 - Provide an option to limit the max number of INT 13h devices presented to system BIOS
UEFI_Driver - 0x06060A01 (Signed)
SCGCQ00618669 - StartHiiBackEnd() has Print statement with %g
SCGCQ00578194 - UEFI Driver should calculate checksum before setting bios data (MR_BIOS_DATA)
SCGCQ00601851 - System hang when we press F1 on second time when we are in HII form
SCGCQ00628627 - UEFI Driver- has debug print statements during POST
SCGCQ00589148 - Diskpart EFI utility can't create partition on a JBOD
SCGCQ00526851 - Support EFI_FIRMWARE_MANAGEMENT_PROTOCOL for controller firmware upgrade.
SCGCQ00579837 - UEFI Driver should calculate checksum before setting bios data (MR_BIOS_DATA)
SCGCQ00606367 - UEFI Driver returns EFI_NOT_FOUND when platform passes valid Target for ExtSPT.BuildDevicePath()
SCGCQ00644856 - Install FMP on Controller Handle at Start() and the exception
SCGCQ00644859 - FMP GetImageInfo could result in stack corruption - Code Review Defect ID D26304
SCGCQ00580313 - User can't access RAID HII in UEFI mode after removing a HDD
Hii - 03.07.12.01 (Signed)
SCGCQ00579816 - HII\EKM-LKM without reboot should show proper message
SCGCQ00594011 - Without selecting any drives I am seeing the previous config VD size.
SCGCQ00609737 - Configuration Restore is not working
SCGCQ00618674 - StartHiiImpl() WriteToLogger uses %g and EFIHiiDriverEntryPoint() Print statement uses %g for displaying EFI status
SCGCQ00521488 - Getting error message when we suspend Patrol read operation through HII browser
SCGCQ00565876 - Remove duplicated strings from the UNI FIle
SCGCQ00571353 - Allow user to select RAID level when controller has other VD + error handling
SCGCQ00573871 - fixing code review defects (AIM version + UCM GUID + deallocation)
SCGCQ00614027 - Firmware updation fails in OEM machine
SCGCQ00615221 - Form UF003 prints error messages (use WriteToLogger to log these debug messages)
SCGCQ00617617 - FWMgmt Prtocol:<config ID="LSIMegaRAIDConfigurationTool"> has no "versionid" info.
SCGCQ00565088 - Help content for Firmware Update in Controller Management is inappropriate
SCGCQ00569098 - Enter security key for locked drives screen, press down to get to OK, OK will show up again on right
SCGCQ00598822 - VD details display is improper in Expand Virtual Drive
SCGCQ00613822 - Advanced Controller Properties- Power Saving Settings has broken form
SCGCQ00556839 - Able to select EKM even when the EKM FOD key is removed from the system.
SCGCQ00589301 - System/HII hang when clicks on Hardware Components menu option in HII.
SCGCQ00595864 - On Success of creating Drive Security Form loads into Advanced controller properties
SCGCQ00598431 - IMR Liberator Drop Down option in VD properties for Cached is present
SCGCQ00610889 - Customize help string for Select Interface Type
SCGCQ00615190 - Fill Controller Index in RouteConfig + for UF003 calculate checksum only for the actual config size
SCGCQ00593558 - Auto Learn Mode is showing wrong data
SCGCQ00612574 - Addressed review comments
SCGCQ00613820 - Typo in HII form Controller Status
SCGCQ00622464 - Toggling between Legacy to Uefi mode vice versa junk values seen .
SCGCQ00524969 - HII PKG 0006/Going from LKM to EKM asks for a Current Security key Identifier and Security key.
SCGCQ00590465 - On selecting a wrong parameter for size while creating VDs, Options greyed, Create VD page exits to parent page.
SCGCQ00595463 - Security feature is enabled but HII sees "Drive Security" as disabled
SCGCQ00571359 - UCM Phase 1: Typo "Clear Configuration" -> "Clear Configuration"
SCGCQ00573222 - Handling Code Collaborator Review Defects for SCGCQ00568814 and SCGCQ00569197
SCGCQ00575062 - added a while loop and take care of the multiple PD Groups scenario.
SCGCQ00578190 - HII should calculate checksum before setting bios data (MR_BIOS_DATA)
SCGCQ00597641 - MR6.3 HII aesthetic change
SCGCQ00503036 - Changing Percentage of Space to Expand Does not Update Final VD Size
SCGCQ00574041 - AIM (Agentless Inventory Manager) Issues
SCGCQ00574989 - Creation+ FW updation+ Scan foreign Configuration is disabled/grayed out in HII page
SCGCQ00614466 - HII 03.07.05.00/Under advanced controller properties and selecting Cache and Memory, it says's "scontroller cache"
SCGCQ00614675 - To address FW Update help Strings
SCGCQ00619028 - Not able to schedule CC in concurrent mode from HII(03.07.09.00).
SCGCQ00526978 - HII. Provide controller FW update function
SCGCQ00568814 - HEFU. Simplify controller property page
SCGCQ00568706 - Remove limitation for creating R6 in HII for OEM
SCGCQ00612466 - Provide pop-up to display current version and update fw version as part of HEFU HII Firmware Update functionality
SCGCQ00571579 - (Implemented) - Create a formset with classGUID that customer has provided.
SCGCQ00569197 - Move Disable Protection option from Controller Management to VD management
SCGCQ00557522 - System hang observed when the "PdInfo.userDataBlockSize" is set to 0
SCGCQ00601110 - Able to select EKM even when the EKM FOD key is removed from the system.
SCGCQ00601103 - Enter security key for locked drives screen, press down to get to OK, OK will show up again on right
SCGCQ00601107 - HII PKG 0006/Going from LKM to EKM asks for a Current Security key Identifier and Security key.
SCGCQ00601119 - HII help for Boot error handling does not display "Stop On Error" option
SCGCQ00644857 - Remove FMP installed on the controller handle in HII
SCGCQ00644858 - RSOD during POST after enabling SecureBoot - HEFU.ROM should report exact size of .EFI image
SCGCQ00629813 - RSOD during POST after enabling SecureBoot - HEFU.ROM should report exact size of .EFI image
SCGCQ00601113 - HII\EKM-LKM without reboot should show proper message
SCGCQ00601117 - UCM Phase 1: Allow user to select RAID level when controller has other VD + error handling
SCGCQ00572986 - System hang observed when the "PdInfo.userDataBlockSize" is set to 0
SCGCQ00644575 - Consistency Check Start - remove mm/dd/yyyy from the string as the format is out of control of LSI
SCGCQ00596920 - Missing BBU caused disappearance of Enclosure Mgmt opt in BIOS setup
SCGCQ00603235 - HII help window shows unsupported stripe sizes
SCGCQ00601116 - added a while loop and take care of the multiple PD Groups scenario.
SCGCQ00601118 - UCM Phase 1: Typo "Clear Configuration" -> "Clear Configuration"
SCGCQ00601120 - In HII on a ready drive we are able to see Used space as 40Gb.
SCGCQ00644786 - Enhance help message for PD/VD Operation field
FCODE - 4.16.08.00
SCGCQ00553069 - PCLI(1.07.05) Sparc: Command "cli set securitykey=Lsi@12345" fails with errcd "1001" and errmsg "invalid key".
IMR NVDATA - 3.1403.01-0061
SCGCQ00709554 - Revise Drive Spin-Up Timing on OEM 12G iMR and MR Boards
SCGCQ00685089 - Addition of ManPage1 values to the xml file.
SCGCQ00696438 - Customer NVDATA Change request for iMR
SCGCQ00692947 - Dual write NVDATA changes for customer
SCGCQ00673357 - Flatwoods Showing Same Slot Number for All Drives
SCGCQ00658482 - breakMirrorRAIDSupport for single span Raid 1
BootBlock - 3.02.00.00-0001
SCGCQ00685115 - Memory/battery problems in Focused Regression
SCGCQ00505902 - Coherency bit is disabled in SRAM TLBs
Ctrl-R - 5.04-0002
SCGCQ00644489 - Added a new Control to enable/disable JBOD on the controller in Ctrl Mgmt page.
SCGCQ00648965 - Display the Battery status as N/A for iMR cards.
SCGCQ00584991 - current write policy is not getting updated until we press f5
SCGCQ00584993 - unable to display the reason for difference in write policy
SCGCQ00593822 - Both the Connector information(0-3 & 4-7) is not shown in PD properties while connected in Multipath
SCGCQ00579583 - Write policy is not added with writeback with BBu when MFC is set
SCGCQ00573077 - VD Erase will be disabled in Ctrl+R when Initialization on particular VD is aborted
SCGCQ00585013 - Added the code to unset the boot-device to NONE
SCGCQ00584991 - current write policy is not getting updated until we press f5 .
SCGCQ00584993 - unable to display the reason for difference in write policy
SCGCQ00593822 - Both the Connector information(0-3 & 4-7) is not shown in PD properties while connected in Multipath
SCGCQ00579600 - Write policy is not added with writeback with BBu when MFC is set
SCGCQ00579607 - VD Erase will be disabled in Ctrl+R when Initialization on particular VD is aborted
SCGCQ00585013 - Added the code to unset the boot-device to NONE
PCLI - 1.07.05
SCGCQ00501437 - StorCLI - MR 6.2 StorCLI help syntax is wrong for R1EC
SCGCQ00518543 - PCLI Sparc(1.07.02):" Cli show all" command fails with error msg "Error! App exec failed in FW PCLIError! Internal".
- CATEGORY:
- Motherboard
- COMPATIBLE WITH:
- OS Independent
- file size:
- 33.8 MB
- filename: