Intel MCB2208WFHY2 Server System OFU Firmware 00.001.0014

Manufacturer:

Description

DOWNLOAD NOW

Versions:

- BIOS : 00.01.0014
- ME : 04.00.04.340
- BMC : 1.60.56383bef
- FRUSDR : 1.60

Changes in BIOS R00.01.0014:

- Rename BIOS ID from X0149 to R0014.
- TPM Update fail on S2600ST and S2600WF
- Update Microcode 0x4d for Xeon Scalable H0 and 0x144 for Xeon Scalable B1
- CCB2334 [PSIRT Factory BMC & BIOS] enabling one-time software update to any version
- [PC Stitching]Update ME SPS version to 340
- [S2600BP] Windows2016 cannot be installed with SATA port5+port7 RSTe RAID0
- Other PCI device's SsidSvid is 0xFFFFFFFF and is different from NIC Controller on SFP+ S2600BP board
- Higher security ID from 1.05 to 1.06 because of HECI PRT and Backup BIOS PRT patch
- BIOS Change for #CCB 2083[Syscfg tool]Add option to configure fan pwm offset in syscfg
- The system will not boot to IPV4 PXE if UEFI Network Stack disabled for IPV6 PXE in BIOS
- [BMC+BIOS]Need mechanism for BMC to return MAC addresses for add-in card on demand
- Toshiba THNSN5128GPU7 M.2 PCIe SSD can't detect successful under Win2016 OS.
- [BIOS] Add Infineon FW update capability support in BIOS and UEFI application
- BSOD after warm reboot if HT is enabled with Windows Server 2016 version 17663 and 17666
- [S2600WF]SMBIOS Type 8 NIC number does not match motherboard number
- [S2600WF&S2600BP]Fix system will hang with POST code 0x94 when one riser slot of HOST connects two WRG JBOD nodes with 32 RSSDs
- BIOS does not return Type 199 records
- Support Relax Ordering and No Snoop in BIOS setup and ITK
- [S2600WF]bios_wp protection has not been enabled
- Add SMBIOS OEM String modification capability in ITK
- After clear CMOS, EWS does not display about CMOS log when boot to BIOS setup
- MMIO size set to Auto/1G can't boot to BIOS with NIC Card-XL710 in Legacy mode
- BIOS Change for #CCB 2083 [Syscfg tool]Add option to configure fan pwm offset in syscfg
- Inject Memory Address Parity error and no error event occurred in SEL accordingly
- Change "CPU Power and Performance Policy" from "Balanced Performance" to "Performance" on the custom BIOS capsule by ITK tool, related items "C1E" cannot be changed automatically.
- CL541242 5386244: BaseTraceHubInitLibNull references non-existing SkylakeSiPkg
- Xeon Scalable 2933 mc transient error
- BIOS NTB PPD Option Setup is Reversed
- Some validated DIMMs have not been included in the DimmWT4 table
- Advanced Memory Test failed at MT_CPGC_READ_WRITE
- HECI_MBAR can be reallocated by ring-0 anywhere in the address map (BIOS vulnerability)
- 2 SKT DEBUG build ASSERTs with a Security Violation
- System hangs after error injection during DIMM Address Translation
- NVDIMM not in memory map when NUMA is disabled
- Enable MSR_VIRTUAL_MSR_LLC_PREFETCH reconfiguration on Skylake B-step
- Add device IDs for QS/PRQ S LBG SKU
- Integration BIOS ACM to 1.3.6 and SINIT to 1.3.3
- [PC Stitching] Update ME SPS version to 333
- BIOS POST messaging shows no errors when in fact a DIMM is mapped out
- Function RemovePsfAccess () is not called with SPS FW binary
- IioEarlyInit.c:IioPciePortEWL() swaps link_width and link_speed in EWL
- Early SEC RC is not properly programming the HPET due to a coding bug, causing a rogue write to memory [IPS 220586227]
- ACPI table will miss some core with some specific bit mask processor
- Clone from 5386949 FW-UEFI-Vuln-2018-008 - "PSIRT-BIOS-2018-008 Additional protection for DCI enable"
- When hotplug NVMe HDDs the RSTe GUI location couldn't match actual HDDs location
- XL710 show the same boot order name in Boot management
- [BIOS] Support more memory vendor DIMMs -- Apacer, ATP, Hyundai, Innodisk, intelimem, V Color
- [BIOS] BIOS support for WFC, WFD, WFS cluster systems
- [S2600BP] Boot manager still shows PCIe device if disable it on PCIe Port Oprom Control. -->Fix CL552580 side effect
- NIC Port Mapping between Chassis and Windows Server OS are inverted on S2600BP SFP+, RJ45, and S2600WFT
- [PC Stitching] Update RSTE Drivers to v5.4.0.1039
- EWS and SEL viewer showed incorrect ME version when online update ME version
- [BMC+BIOS]Need mechanism for BMC to return MAC addresses for add-in card on demand
- Add two APIs in fast video PPI and protocol
- [S2600WF] After downgrade FD and ME, SUT will halt with beep code 1-5-1-2 when rebooting

Changes in BMC v1.60.56383bef:

- [S2600BP] BMC is not reporting redundancy lost by clearing STATUS_INPUT flags from PSU
- [S2600WF]The AIC Product Name information returned is replaced by part MAC address of the third cards when the connected AIC Cards are greater than two.
- BMC User and Network setting will change to default after online update BMC to 1.59.ba077703&AC cycle
- [S2600BT]SSL/TLS use of weak RC4 cipher
- [S2600BT]Birthday attacks against TLS ciphers with 64bit block size vulnerability (Sweet32)
- [S2600ST] Chinese characters are not displayed properly in Event Log page while login Web in Chinese
- Q2'18 #CCB2434 [Purley BMC]Implement 0xD5 return code when the user requests power on and the system is already on
- Completion code for OEM get sensor reading(platform power consumption) isn't right when no ADM chipset is available.
- BMC User and Network setting will change to default after online update BMC to 1.59.ba077703&AC cycle
- [S2600BT] Media will be unmounted after booting into OS
- [S2600WF] Media will be unmounted after booting into OS
- [S2600BT] Event log page can't be read via IE browser
- [S2600WF] The Event Log shown abnormally on EWS after pressed NMI Button.
- EWS: Use Firefox browser to check the system event log, all the information is unreadable code unless clearing the browser cache
- EWS: There is an unreadable character in the system event log
- EWS: When setting the language to Chinese, the event log information show unreadable characters
- EWS: It could not establish the session to EWS after setting the https port to a customized value
- [S2600BT] BMC can't stuck in Safe mode after execute 4 times BMC watchdog
- [S2600BT] HTTPS Port can't log in from other values after HTTPS Port modify 8443
- Remote ipmitool chassis power off returns error when chassis is already off.
- [KVM/VM] Virtual Media redirection fails installing OS and console spews SSL errors
- [S2600BP LCR]Sensors are not correctly displayed in one cycle when run AC/DC cycle test
- [S2600BT] Enable Remote Debug function command response incorrect via BMC Shared LAN IP

Changes in FRUSDR 1.60:

- Enable "PS[x] Fan Fail" for 1600W PSU
- Enable median filter for hidden voltage sensors.
- Add support for 1600W psu.
- Updates to version 30 of FSC spreadsheet
- Adds remote PECI support to the Remote Debug sensor
- HSD 2103619689 - Includes NVMe sensors for 123.5 HSBP
- HSD 2202506519 - Updates CPU name in master.cfg display
- Adds processor absolute temp sensor
- Removes unused UPI Fatal sensors
- Updates to version 29 of FSC spreadsheet
- CCB1904 Adds support for Riser 3 temp sensor detection
- Adds FW Security sensor

GENERAL INSTALLATION PROCEDURE

1. Unzip the contents of the update package and copy all files to the root directory of a removable media (USB flash drive)
2. Insert the USB flash drive to any available USB port on the system to be updated
3. Power on the server and load the uEFI shell
4. Begin the update process running the Startup.nsh
5. Reboot the system after the update process has successfully completed

Web GUI update

1. Unzip the package onto your system
2. Log into the BMC web GUI
3. Navigate to Configuration, then Firmware Update
4. Click browse, and direct the browser to the location of Purley_1.04.f80688d0.bin
5. Click upload. Progress and status will be shown as the update progresses

UEFI update

1. Unzip package and load onto a flash drive
2. Boot to UEFI shell, and navigate to the folder where this package lives
3. Run fwUpdateBMC.nsh and follow the prompts

Verifying Updates:

01. After the final update has completed successfully, reboot the system
02. During POST, hit the <F2> Key when prompted to access the BIOS Setup Utility
03. From the BIOS Setup Utility main menu, hit the <F9> key to load BIOS defaults
04. Hit the <F10> key to Save Changes and Exit the BIOS defaults
04. At the main menu verify the BIOS revision is correct
05. Move cursor to the SERVER MANAGEMENT menu and hit Enter
06. Move cursor to the SYSTEM INFORMATION Option and hit Enter
07. Verify the BMC Firmware revision is correct
08. Verify the SDR revision is correct
09. Verify the ME Firmware revision is correct
10. Configure desired BIOS Option settings
11. Hit the F10 Key to Save Changes and Exit  

About Firmware Updates:

Applying a newer firmware version than the one already installed on your unit can bring various enhancements, include workarounds for diverse problems encountered by the device, and improve or add newly developed features.

On the other hand, downgrading the firmware version can recover the device's functionality in the event of a software update either turning up faulty or causing the unit's overall performance to drop. However, bear in mind that applying an older firmware isn't recommended and might not always be possible.

When it comes to the update steps, due to the large variety of devices and numerous ways for installing a new firmware, it is recommended that you carefully read and understand the upgrade steps, and consider applying a different firmware only when you have familiarized yourself with the update method.

As the installation process is most of the times quite risky, this step should be taken by users that have the ability to successfully complete the update; regular users may initiate it at their own risk. Moreover, it's best that this task be performed in a steady power environment such as the one ensured by a UPS unit.

Therefore, if you consider applying this release, hit the download button, take into account all the aforementioned aspects, and update the device's firmware. Also make sure you constantly check with our website to ensure that you don't miss a single new release.

Intel MCB2208WFHY2 OFU Firmware Intel MCB2208WFHY2 BIOS Intel MCB2208WFHY2 Firmware MCB2208WFHY2 OFU Firmware Intel Server System

  CATEGORY:
Firmware
  COMPATIBLE WITH:
OS Independent
  file size:
31.6 MB
  filename:
S2600WF_SFUP_BIOSR0014_ME04.00.04.340.0_BMC1.60.56383bef_FRUSDR1.60.zip