Intel HNS2600BPQ24 Compute Module RAID Firmware 50.5.2-1326

Manufacturer:

Description

DOWNLOAD NOW

Firmware Changes:

SCGCQ01566087 - JBOD devices were dropped after unloading driver and reloading driver in linux
SCGCQ01571588 - backend PCIe: 4311 fault (part 3)
SCGCQ01577475 - 9440-8i card: drop out UG drive, error LED always ON. Error LED turns off only upon reinsertion of the drive.
SCGCQ01583517 - sysDMA attempted on core1 cause FW crash
SCGCQ01605610 - Task Management due to SATA init failure results in resource error message
SCGCQ01575182 - BIOS Handshake breaks Manufacturing Environment, need change in TTY and/or add timeout in FW for BIOS Handshake
SCGCQ01614688 - 7.5 R1 performance change request.
SCGCQ01574924 - pl: backend PCIe: 4311 fault (part 3)
SCGCQ01581911 - Fixing the issues during bringup of the universal backplane.
SCGCQ01582240 - To fix issues for back plane configuration validation and LED control for the UBM backplane.
SCGCQ01582246 - To fix the LED issue, VPP data and moving to change detect poll state
SCGCQ01582497 - Event with enclose 0x00 slot 0 during the system boot when a command is timed out (Command timeout on PD 12(e0x00/s0))
SCGCQ01582503 - STP Passthru commands end up with blank FiS response buffer
SCGCQ01582535 - 9460-8i is reporting Chip Temperature of 255 when the ambient temp is about 0 C
SCGCQ01598554 - Slot status LED updates to certain slots on NVMe backplane may fail
SCGCQ01599743 - Restrict FW update based on NVMe external clock oscillator support of current SBR and inbound SBR image
SCGCQ01602617 - Add logging messages in addition to changes for SCGCQ01520443
SCGCQ01615762 - Enclosures is not exposed to Host even if exposeEnclosureToHost is set.
SCGCQ01582244 - To fix the phy to slot mapping issue for the UBM backplane
SCGCQ01582532 - CC doesn't start on special built OEM firmware
SCGCQ01593192 - (SATA Only) SCSI Unmap command to some SATA drives are timing out.
SCGCQ01540362 - Linux driver incorrect issuing MR_DCMD_DEV_GET_TARGET_PROP to enclosure devices
SCGCQ01601702 - pl: NVMe: Write Long (10) fails when LBA exceeds 0x7FFFFFFF
SCGCQ01627798 - divert bitmap not enabled on R5/R6 WT Vds
SCGCQ01454613 - Pausing progress operation and resuming shows it starting from 0 again and abruptly moves to actual progress after a while
SCGCQ01478170 - Direct attached NVME drives are not getting associated with vSES in Microsoft Storage Spaces Direct.
SCGCQ01479406 - Drive addition in OS takes longer time when Drives are connected with certain backplanes to the controller
SCGCQ01484382 - improved fix for 6001 fault
SCGCQ01485060 - (SATA Only) Format of SATA SSD takes long time
SCGCQ01485441 - Firmware Download does not protect user from downgrading to firmware
SCGCQ01486695 - Host application hangs waiting for completion of IO issued after NVMe device is removed
SCGCQ01487291 - switch attached devices not detected under Windows
SCGCQ01491291 - OOB SLT get errror when getting send, getobjstatus and getttylog.
SCGCQ01498117 - Controller fail to be detected by BIOS and OS after FW downgrade MR73 with COL.
SCGCQ01502112 - Hit Assertion failure in ../../hw/pce/fusion.c at line 1847 after loading the driver & reboot
SCGCQ01502700 - Report Zone for very large data of 4MB takes ~2 seconds for processing
SCGCQ01503262 - FW may fault on single bit correctable ECC errors in IOA Local RAM
SCGCQ01504284 - additional phy hardware cleanup on link down and hot reset
SCGCQ01504310 - LTSSM state wait during hot reset
SCGCQ01504936 - New Event required for individual PD PR completion
SCGCQ01507024 - FW hit assertion failure when booting up with enclosure attached
SCGCQ01509537 - Auto rebuild does not start when HS has PF
SCGCQ01509632 - (SATA Only) SCT Error Recovery Control read using ATA Passthrough is not returning correct values.
SCGCQ01509791 - Assertion failure in ../../cpu/arm/exceptions.c at line 938 observed, while destaging preserved cache on R0 DG
SCGCQ01510251 - Fix Temperature Throttling
SCGCQ01518712 - FW incorrectly reports LD unit attention pending irrespective of the scsi op code
SCGCQ01519732 - 4311 fault with NVMe enabled
SCGCQ01522342 - 4311 fault with NVMe enabled (part 2)
SCGCQ01522362 - Firmware asserted at memory.h at line 443: isInAddressibleRange when push/pull JBOD NVMe drives
SCGCQ01522492 - Address performance issue for CPU intensive profiles.
SCGCQ01522509 - Firmware reports iopiTimedOutIOFound when running IO on NVMe JBOD drives
SCGCQ01529400 - Spin up large config drives by load the config file while they are in POWERSAVE, caused FW hit DrvSpinup.c @line 1362
SCGCQ01531736 - SR, RR, and OLTP regressions up to -90% on 24 Single Drive R0 Config
SCGCQ01545274 - Change CmdIgnoreLdUnitAttention() from _IOPATH to static inline
SCGCQ01548923 - system hangs during the reboot test at boot.
SCGCQ01561552 - OOB slt can not see the imr controller
SCGCQ01563926 - OEM name Characters seen in HII Drive management instead of port information.
SCGCQ01566825 - Changing personality between RAID and JBOD resulted in firmware assertion
SCGCQ01566954 - Change UNMAP support from enable to disable
SCGCQ01334586 - Task Management request of Abort Task to an NVMe device completes with failure status
SCGCQ01406527 - PL 00005851 hit while issuing OCRs with IO
SCGCQ01451278 - link may fail to come up after link break
SCGCQ01487866 - Intermittent Update firmware failed with M0 using EFI StorCLI
SCGCQ01489030 - Global HDD LED may not indicate IO activity for NVMe or SAS drives
SCGCQ01494379 - 0x7C41 Fault doing IOs and Task Managements on a mixed SAS/NVMe topology.
SCGCQ01496842 - port enable may time out on spinup failure
SCGCQ01505392 - Slot LEDs on SGPIO based backplane may not blink
SCGCQ01509362 - Firmware asserted at ddf/ddf.c at line 1377: ld == vdRec->Populated_VDEs when insert NVMe drives
SCGCQ01511995 - OEM Drive Activity LED Stays On
SCGCQ01516975 - Firmware hang during power up after power failure with COL
SCGCQ01525140 - Firmware hangs due to DISM not completing
SCGCQ01555097 - Firmware asserted during cable pull with IO on JBODs and taskmgmt reset
SCGCQ01561897 - After VD erase, In the Action menu, It is not changing from Stop Erase to Erase
SCGCQ01502102 - Assertion failure in ../../dm/mpt2/mptframe.c at line 1250: mptIo!=NULL
SCGCQ01503916 - erroneously called bvdInfoSort() in DDF_ConfigRead() causes DDF to be corrupted
SCGCQ01505522 - Cannot set Foreign UBad to Foreign UGood with a config of 31 VDs and iMR 9441-8i
SCGCQ01519710 - Dump pending driver IO completions from task context during kill adapter debug
SCGCQ01531146 - Kill Adapter when create vd
SCGCQ01538991 - Enable MR code for generating firmware not compatible with profile event
SCGCQ01468157 - RAID Personality - R0 WB SW 4/8K all QD regression RHEL
SCGCQ01484398 - RAID-5 Hardware Key No Longer Functional
SCGCQ01488410 - 30% to 35% JetstressDB Average Write Latency regression found in R5
SCGCQ01509463 - fw got data abort when connect more enclosure than max in iMR.
SCGCQ01518446 - pdCOD content is being overwritten when using storelibtest to issue SCAN FOREIGN
SCGCQ01522814 - All VDs are not getting deleted after the vd erase operation with 'delete VD after erase' option is selected
SCGCQ01505906 - passCount not incremented for Ctlr Self Diag Link Test
SCGCQ01512359 - web UI is exposing personality change option for iMR controller
SCGCQ01436268 - Add Test Link Diagnostic API
SCGCQ01459401 - Cleanup MR FW log
SCGCQ01531388 - Disable deallocation support
SCGCQ01559697 - Provide print in termlog that shows which I2C address is used for the LED signaling of NVMe drives
SCGCQ01459375 - Use Sense Data from SATA Log Page 10 when querying Log Page 10
SCGCQ01506822 - Resetting discovered flag when prepare for endpoint discovery control command.
SCGCQ01558893 - FBU345 should show as CVPM05
SCGCQ01512568 - Remove deallocation support
SCGCQ01468156 - Limit printing a SGL chain to only 15 elements.
SCGCQ01481032 - SSD can not show the "Part Number"/ "FRU Number" information
SCGCQ01481034 - CATERR reported on front panel LCD and SUT hang at the windows logo page
SCGCQ01496768 - System will pop up “Cannot communicate with iButton to …” during reboot with OEM custom card
SCGCQ01501951 - Switching back and forth between profile 10 and 12 with data cable pull results in foreign config not importable
SCGCQ01505077 - 0x265D Fault Observed on Cold Boot of Customer Server with Misconfigured Controller NVDATA
SCGCQ01505080 - SCSI Write Buffer Mode 7 Command Incorrectly Failed by Firmware
SCGCQ01508067 - Slave response mode fails to return response to I2C read
SCGCQ01508156 - Controller hangs after warm reboot in presence of pinned cache
SCGCQ01510341 - Preserved Cache doesn't flush back during Foreign Import
SCGCQ01511969 - controller reset seen while importing 32 VD foreign config
SCGCQ01514262 - Fault State (0x265d) is Observed While Connecting an Enclosure with Fully Populated SATA Drives
SCGCQ01516692 - iMR-FW Drive Fault LED will light at some frequency when a JBOD drive is pulled out
SCGCQ01519802 - workaround timer may trigger after too short of an interval
SCGCQ01522339 - Controller hang when updating PD fw
SCGCQ01522511 - rapid device removal/add with a specific vendor backplane
SCGCQ01523550 - 4311 fault with NVMe enabled (part 2)
SCGCQ01529383 - non-NVMe endpoint not cleaned up on removal
SCGCQ01529512 - Fault 0x5862 seen when host buffer size is smaller than allocation length in CDB
SCGCQ01538948 - Sles12 SP3 OS is getting stuck during first boot
SCGCQ01539840 - PL Fault 0000ecdd LR 01403837 during initial discovery
SCGCQ01540255 - Initiate ocr when FW enters MonTask
SCGCQ01540360 - Termlog/UARTlog - messages sometimes missed in Termlog
SCGCQ01556426 - switch attached discovery takes too long
SCGCQ01561914 - Jbod become Ugood sometimes after reboot
SCGCQ01562034 - Controller hung, when updating the drive firmware
SCGCQ01562098 - Performance Improvements
SCGCQ01567485 - Check Consistency doesn't identify double media errors once aborting and starting CC again
SCGCQ01581266 - Turn off GPIOA19 (global fault LED installed) correctly at boot time
SCGCQ01421231 - I2C traces shows partial response/zeroâ€ed out packet response from the HBA
SCGCQ01481100 - 930-24i/9460-24i and 930-8i/9460-8i create raid1 with 4 HDD, can't expand VD in UEFI
SCGCQ01511224 - Raid card loss during Test
SCGCQ01512617 - PL owned mids are not getting released even after removing drives (SATA)
SCGCQ01519729 - hardware does not like the IOP enable method used here.
SCGCQ01520063 - storcli show phyerror will return error in some test in some scenario
SCGCQ01521377 - MR FW is setting GPIO_SET_BBU_ENABLE(GPIOA8) wrongly in OCR case.
SCGCQ01524353 - (SATA Only) LBPRZ bit in VPD page 0xB2 is never set for SATA devices
SCGCQ01524448 - MegaRAID BIOS didnot timeout and cause Server boot hung when Controller Boot Fail because of bad SPD
SCGCQ01526202 - iMR FW locks up and PSOD seen while trying to flash MR7.2.1 FW ROP
SCGCQ01530310 - Controller is not detecting in the storelib, after changing the mode from "set mode oob" command
SCGCQ01533267 - EC0D fault
SCGCQ01556893 - link workaround not sufficiently coordinated with SAS link establishment
SCGCQ01561912 - storcli shows 8ports controller as 9 ports
SCGCQ01574395 - System hangs after performed Cryptographic Erase on SAS ISE drive
SCGCQ01499168 - Enhance SAS3 FW to pass PCIeCV PCIe Configuration Validation TD_1_28 Vital Product Data Capability Test
SCGCQ01505145 - When upgrading from 678 10.0 to 10.1 886 and switching to 240VD, unable to create 240VD
SCGCQ01520574 - 4311 fault with NVMe enabled
SCGCQ01521373 - Controller can not correctly detected smart error SATAA HDD.
SCGCQ01524638 - (SATA Only) Security Protocol In command complete without data transfer for allocation length not a multiple of 512
SCGCQ01527219 - PCIe reconfiguration may occur during NVMe controller reset
SCGCQ01558211 - Continuous error( MptHostCmdDone cmdId=fe lmid=8a2:1851b400 tid 04 devH ..) in firmware log when run I/O on NVMe drive
SCGCQ01559005 - Revised "Avoid Duplicate Mid" Feature Code Could Incorrectly Allow IO to Start Through PL Firmware Path
SCGCQ01561911 - Assertion failure in ../../mros/mem.c : mb->tag==tag
SCGCQ01577461 - Fault LED behavior is not consistent between PD direct attached vs connected via expander
SCGCQ01516689 - storcli /c0 show termlog didnot get termlog sometimes
SCGCQ01530305 - Get VDM Support command does not have VendorID and VendorAddInfo fields properly populated
SCGCQ01504375 - Disable write cache to default
SCGCQ01520061 - OCR is disabled by default is RC build, even NVDATA if it is enabled.
SCGCQ01540335 - FW automatically delete and create the EPD's with assigning EPD no 3f indefinitely.
SCGCQ01530478 - DUP failure on OEM controller while I/O is running in background
SCGCQ01503207 - Add method to determine Ring Buffer Overflow in RMC
SCGCQ01459626 - Assertion failure in ../../raid/taskman.c at line 342 while running TM sg_reset on SATA drives
SCGCQ01467284 - Optimize abort handling in command block context.
SCGCQ01467357 - Firmware crash when format drive to PI support
SCGCQ01473186 - To check if NVRAM changes related to upgrade/downgrade issue is present
SCGCQ01473242 - Firmware needs block certain user initiated operaations while it is in pending transition from one profile or personality to another
SCGCQ01450092 - MR RAID-mode profile 10 create vd cause pds for that vd offline
SCGCQ01454233 - WG:LSA in JBOD mode supports creating VD with "Always WriteBack" write policy
SCGCQ01476342 - Assert can occur when applying iButton/iButtonless Licensing settings that is typically done in a manufacturing environment.
SCGCQ01478714 - Unable to set RAID profile 11 & 12 (ROP 820 and newer affected)
SCGCQ01482688 - Additional changes needed for SCGCQ01470741: 16i Cannot Spinup HDD During System Power On.
SCGCQ01473960 - Block personality change when EPD security is not safestore managed.
SCGCQ01484398 - RAID-5 Hardware Key No Longer Functional(ROP 834 & earlier is okay)
SCGCQ01463522 - New feature to disable JBOD through NVDATA change if requested by customer
SCGCQ01464952 - Support for disabling personality modes
SCGCQ01474267 - Disallow mixture of NVMe drives and SAS/SATA drives in VD creation
SCGCQ01458621 - PL: EnclMgmt: Move ownership of SES Page 0x0A slot mapping from devices to PHYs
SCGCQ01487260 - MPI SEP request to Slots with invalid SES Page 0A element index may not complete
SCGCQ01479658 - pl: NVMe: port enable may complete before devices link up
SCGCQ01478827 - pl: NVMe: issues related to port enable completion
SCGCQ01461851 - PL trying to perform memory move using address which is in the non-addressable range
SCGCQ01459637 - pl: backend PCIe: erroneous address pool copy
SCGCQ01460622 - ONFI Device param page checksum calculation is not correct.
SCGCQ01466376 - Fast Path IO is not failed for LDBBM table entries
SCGCQ01473774 - I2C controller hang is observed with repeated LD create and delete script from BMC
SCGCQ01474118 - Max supported disk of Raid 50 and Raid 60 is showing 138
SCGCQ01482233 - 9460-8i card connect drive through direct-attached backplane: error LED not on when drop out a drive.
SCGCQ01483186 - Factory default restore required to set the controller properties after FW upgrade
SCGCQ01496629 - Global HDD LED may not indicate IO activity for NVMe or SAS drives
SCGCQ01459785 - Uncorrectable Medium / DIF Errors are not being handled correctly with pi enabled VDs.
SCGCQ01459793 - Fatal FW Error during CopyBack and partial VD creations on a spanned VD.
SCGCQ01466377 - IO Stress Automation test failed while trying to delete VDs; OCR seen in TTY
SCGCQ01474091 - Inserting enclosures results in unconfigured good PDs changing to R0 automatically and should not
SCGCQ01474449 - Assertion failure in ../../raid/cache.c found while running multipath push/pull with IO'
SCGCQ01478865 - 16i Cannot Spinup HDD During System Power On
SCGCQ01482228 - Fixed the issue with older ibutton
SCGCQ01470577 - Controller hangs after updating to latest ROP 676
SCGCQ01458055 - OS hung and iMR FW reset when do delete and create VD from previous powersave PD (Spindowned)
SCGCQ01459797 - Replace Member PD failed to copy back on a 4KN data protected VD
SCGCQ01473796 - set jbod on a Faulty disk will take several minutes to go to bad state
SCGCQ01487806 - Disable T10 Protection Information support
SCGCQ01404432 - Update nvram.h with correct size for curAdpPersonality
SCGCQ01415120 - Raid Map and Pd sync are updated for every OCR
SCGCQ01408312 - Reduce number of block-pairs used for 8GB offload
SCGCQ01418180 - NVDATA: Change Default SGPIO electrical driving strength from 50 to 66 Ohm
SCGCQ01421427 - Data abort exception during OCR with JBODs
SCGCQ01424266 - Revert SCGCQ01418180 for 3616 and 3508 XSD, 3408 and 3416 remains the same.
SCGCQ01425554 - Integrate MR PL-SCS Libs
SCGCQ01388735 - Store the RAID SubDevID in NVRAM to have a reference to original RAID-ID - NVRAM changes
SCGCQ01373260 - [NVRAM] Warning removal 1295
SCGCQ01421154 - Prevent Improper Flash from ISSI Supported SBR/FW to non-ISSI Supported SBR/FW when Board has ISSI Chip
SCGCQ01413785 - Parameter Page Reads fail during ONFI bringup.
SCGCQ01412186 - pdRef filled incorrectly in bvd->Physical_Disk_Sequence[] causing DDF to skip added PD in Recon
SCGCQ01421154 - Prevent Improper Flash from ISSI Supported SBR/FW to non-ISSI Supported SBR/FW when Board has ISSI Chip
SCGCQ01411024 - Flash write Failed with err code 5
SCGCQ01411329 - Shutdown command received from host" missed in tty log

UEFI Driver Changes:

SCGCQ00883008 - Profile Mgmt API Changes
SCGCQ00927738 - Reintroduce numSGEExt Field in Raid Context to support 1MB IO
SCGCQ01405242 - Enable WB support via API
SCGCQ00948535 - The code had events with repetitive ID and some structures clashing
SCGCQ01403193 - Form set title displayed as <> in HII
SCGCQ01407043 - If waitForKey is False suppress "Enter Your Input Here:" string
SCGCQ01452207 - UEFI Driver skips showing boot message when FW sets Wait For Key Variable with 0
SCGCQ01264142 - New fault code for routine synchronous reset
SCGCQ00867953 - profile management API
SCGCQ01023741 - MR_CTRL_INFO expansion from 2K to 4K
SCGCQ01059740 - mega api changes for ibuttonless PR
SCGCQ01075821 - Profile Management Changes to support requestedProfileID and optimisedProfile
SCGCQ01407767 - If waitForKey is False suppress "Enter Your Input Here:" string
SCGCQ01384314 - With pinned cache generated, HII is auto launched during system Boot when BIOS Mode is set to Ignore Errors.
SCGCQ01447716 - UEFI Driver: For STP Frame data buffer is not copied
SCGCQ01384316 - With pinned cache generated, HII is auto launched during system Boot when BIOS Mode is set to Ignore Errors.
SCGCQ01447720 - UEFI Driver : System Hangs on running SCT test
SCGCQ01452207 - UEFI Driver skips showing boot message when FW sets Wait For Key Variable with 0
SCGCQ00867953 - profile management API
SCGCQ00875328 - Mega API modifications needed for RMW-FP and Cache bypass features
SCGCQ00941620 - de-feature AHCI
SCGCQ01023741 - MR_CTRL_INFO expansion from 2K to 4K
SCGCQ01059740 - mega api changes for ibuttonless PR
SCGCQ01203751 - Isolating faulty cable issue from bad drive issue
SCGCQ01227051 - New events for PR/CC conflicts and sector size mismatch
SCGCQ01447718 - UEFI Driver: For STP Frame data buffer is not copied
SCGCQ01474307 - UEFI driver to handle applications NOT setting direction flag
SCGCQ01558862 - SCSI frame length not matching with SGL count
SCGCQ01452594 - UEFI Driver skips showing boot message when FW sets Wait For Key Variable with 0
SCGCQ01447716 - For STP Frame data buffer is not copied
SCGCQ01447723 - System Hangs on running SCT test
SCGCQ01478749 - Remove FMP Support From UEFI Driver
SCGCQ01447720 - System Hangs on running SCT test
SCGCQ01407043 - If waitForKey is False suppress "Enter Your Input Here:" string
SCGCQ01345378 - MR7 PNP additions
SCGCQ01351616 - Change the logic for reentering to main entry point in UEFI Driver
SCGCQ01384314 - With pinned cache generated, HII is auto launched during system Boot when BIOS Mode is set to Ignore Errors.
SCGCQ01321203 - Reset Type and customer messaging for system resets initiated by controller OpROM
SCGCQ01321228 - When user unloads UEFI Driver nullify pHiiHandShakeProtocol and ask platform to free HII (memory and image handle)
SCGCQ01301650 - Cursor below text and in center of line on the system reset request screen.
SCGCQ01309119 - Debug print shown on the console from the UEFI Driver error path.
SCGCQ01349428 - Firmware Management Protocol - Firmware update fails with inappropriate message when trying to update an unsigned
component

Hii Changes:

SCGCQ01447718 - For STP Frame data buffer is not copied
SCGCQ01449687 - JBOD Mode – SAS/SATA Large Topology Support (240 PD/VD) (WT for VDs)
SCGCQ01474307 - UEFI driver to handle applications NOT setting direction flag
SCGCQ01558862 - SCSI frame length not matching with SGL count
SCGCQ01491187 - Attached Enclosures/PDs do not enumerate correctly in HII.
SCGCQ01452594 - UEFI Driver skips showing boot message when FW sets Wait For Key Variable with 0
SCGCQ01486435 - PCIe PD interface type still showing as an option for OEM Controller
SCGCQ01524609 - Add Device Speed options for PCIe drives
SCGCQ01558992 - Unable to select Option to discard preserved cache in HII.
SCGCQ01447723 - System Hangs on running SCT test
SCGCQ01478749 - Remove FMP Support From UEFI Driver
SCGCQ01478752 - Profile management: Do not show "Max PCIe Count" if MR_CTRL_INFO.adapterOperations5.supportPCIe is set to 0
SCGCQ01397706 - Check All option is not working properly in Make JBOD form
SCGCQ01403193 - Form set title displayed as <> in HII
SCGCQ01404248 - HII: Controller Name is not shown in the HII Formset title
SCGCQ01407043 - If waitForKey is False suppress "Enter Your Input Here:" string
SCGCQ01388767 - HII is showing the internal backplane drives in triplet format instead of duplet.
SCGCQ01401629 - Secure Virtual Disk checkbox not selected by default when Security is Enabled on the controller
SCGCQ01405002 - HII Controller mode[JBOD] :Check All option not available to Make JBOD
SCGCQ01405359 - Question value mismatch in profile management
SCGCQ01413295 - HII: Read VPD and display SN in HII accordingly and update the Inventory data with default values when keyword is missing in VPD
SCGCQ01445619 - HBA (Host Bus Adapter) String is used twice instead of SDS (Software Defined Storage)
SCGCQ01397564 - The physical drive operation % increase in progress is not getting updated
SCGCQ01427258 - Suppress Emulation Type for 4k VD
SCGCQ01452207 - UEFI Driver skips showing boot message when FW sets Wait For Key Variable with 0
SCGCQ01376325 - An empty page is seen when reconstruction is triggered.
SCGCQ01404996 - HII Controller mode[JBOD] :Warning massage is not displayed in Make JBOD
SCGCQ01387373 - "The requested command has invalid arguments" message is seen after importing 150+ virtual drives.
SCGCQ01388677 - Connector Name is truncated in the "Disk Name string" in Disk Management
SCGCQ01396828 - Unable to convert all UG drives to JBOD while 2 enclosure connected
SCGCQ01406386 - Internal Backplane is showing as an enclosure in HII Dashboard View
SCGCQ01407025 - Check All is not working in Assign Dedicated HotSpare form
SCGCQ01411539 - Use SetBrowserData for VD and PD Mngt Refresh functions.
SCGCQ01412729 - HII - Select Span option shown after creating a VD with no Unconfigured drives remaining
SCGCQ01405000 - HII Controller mode[JBOD] :Error massage displayed upon converting UG to JBOD
SCGCQ01406429 - HII shows junk characters instead of serial number when you go to Controller Management Page.
SCGCQ01289924 - Add "Incompatible with Profile" event
SCGCQ01445048 - Add a new structure to provide OEMs ability to switch to select either I2C or PCIe as an out of band transport
SCGCQ01386211 - UEFI Driver: MR/iMR PCI Generic Information Retrieval from MPB Entry
SCGCQ01406093 - JBOD Mode – SAS/SATA (64 Physical Drive/Virtual DriveD) (Write back for Virtual Drives)
SCGCQ01336996 - HII: MR/iMR PCI Generic Information Retrieval from MPB Entry
SCGCQ01394969 - JBOD Mode – SAS/SATA Large Topology Support (240 PD/VD) (WT for VDs)
SCGCQ01400115 - The physical drive operation % increase in progress is not getting updated
SCGCQ01447705 - Submit Fail for Form: Dashboard view for HII/Storage management forms
SCGCQ01419755 - HII - Select Span option shown after creating a VD with no Unconfigured drives remaining
SCGCQ01407767 - If waitForKey is False suppress "Enter Your Input Here:" string
SCGCQ01392392 - Connector Name is truncated in the "Disk Name string" in Disk Management
SCGCQ01389130 - In the 'Manage SAS Storage Link Speed' form, not able to move the cursor to the next entry.
SCGCQ01385162 - For SuperCap, HII has the primitive 'Remaining Capacity' which is different compared to other host utilites
SCGCQ01454099 - Not able to change Security passphrase after selecting the check box "use existing passphrase".
SCGCQ01452578 - RLM option not listing for Raid 0 VD created on SSD when there is existing R1 VD with HDD
SCGCQ01449677 - Enclosure count is wrong in HII Dashboard form
SCGCQ01402885 - Unable to convert all UG drives to JBOD while 2 enclosure connected
SCGCQ01388946 - "The requested command has invalid arguments" message is seen after importing 150+ virtual drives.
SCGCQ01426500 - Per HII NGM design doc rev 1.3, HII not to show Connection field under basic pd prop page for OEM BP
SCGCQ01402889 - HII is showing the H745P MX internal backplane drives in triplet format instead of duplet.
SCGCQ01402883 - Check All option is not working properly in Make JBOD form
SCGCQ01384314 - With pinned cache generated, HII is auto launched during system Boot when BIOS Mode is set to Ignore Errors.
SCGCQ01447677 - SATA PD information is missing on OEM controller in HII
SCGCQ01447658 - help String change request for "Select Raid Level" for RAID 60
SCGCQ01407030 - Check All is not working in Assign Dedicated HotSpare form
SCGCQ01423426 - Internal Backplane is showing as an enclosure in HII Dashboard View
SCGCQ01416004 - Add Device Speed under Advanced PD properties page
SCGCQ01389129 - In the 'Manage SAS Storage Link Speed' form, not able to move the cursor to the next entry.
SCGCQ01447716 - UEFI Driver: For STP Frame data buffer is not copied
SCGCQ01386799 - Not able to disable JBOD mode when there is file system/operating system present on the controller configuration.
SCGCQ01426465 - HII - PD ordering is based on slot id rather than enclosure id
SCGCQ01386798 - Not able to disable JBOD mode when there is file system/operating system present on the controller configuration.
SCGCQ01384316 - With pinned cache generated, HII is auto launched during system Boot when BIOS Mode is set to Ignore Errors.
SCGCQ01422005 - change Default setting in Select Media Type in HII from HDD to Both
SCGCQ01422002 - iMR HII will jump to some form unexpectedly when import foreigh configuration
SCGCQ01491729 - Attached Enclosures/PDs do not enumerate correctly in HII.
SCGCQ01464680 - Unable to create a R10 in HII but can with CLI
SCGCQ01447734 - Issue with Uneven Span
SCGCQ01447720 - UEFI Driver : System Hangs on running SCT test
SCGCQ01447698 - HII : System Hangs with Assert on running SCT test
SCGCQ01447088 - Question value mismatch when converting JBODs to UGs during VD creation
SCGCQ01467531 - Create Virtual Drive: The Yes option that user chose gets retained for Disable Background Initialization
SCGCQ01330410 - Add Requeted Profile ID field in Profile Management form.
SCGCQ01397706 - Check All option is not working properly in Make JBOD form
SCGCQ01407043 - If waitForKey is False suppress "Enter Your Input Here:" string
SCGCQ01388767 - HII is showing internal backplane drives in triplet format instead of duplet.
SCGCQ01401629 - Secure Virtual Disk checkbox not selected by default when Security is Enabled on the controller
SCGCQ01343778 - Question ID assignment for item under suppressif TRUE and the same item that gets created at runtime
SCGCQ01344008 - HEFU: Delay seen during boot in case of 240 PD configuration.
SCGCQ01344658 - Customize the configuration help message.
SCGCQ01355025 - Silence Alarm: Use tech pub suggested help string
SCGCQ01379764 - HII Advanced VD properties shows "CacheCade Type" primitive
SCGCQ01376325 - An empty page is seen when reconstruction is triggered.
SCGCQ01372698 - LockKeyFailed is set with junk value from Controller info
SCGCQ01387373 - "The requested command has invalid arguments" message is seen after importing 150+ virtual drives.
SCGCQ01388677 - Connector Name is truncated in the "Disk Name string" in Disk Management
SCGCQ01396828 - Unable to convert all UG drives to JBOD while 2 enclosure connected
SCGCQ01406386 - Internal Backplane is showing as an enclosure in HII Dashboard View
SCGCQ01352041 - RSOD seen when user browse to Enclosure Management Page
SCGCQ01354659 - HII Create Virtual Disk option is selectable even before choosing drives for the VD
SCGCQ01412729 - HII - Select Span option shown after creating a VD with no Unconfigured drives remaining
SCGCQ01348156 - Foreign Configuration Preview screen also has entries of virtual drives that are optimal in state.
SCGCQ01337568 - HII: Enumeration of drives
SCGCQ01335254 - Prompt string should be unique
SCGCQ01345617 - Remove unsupported features from the HII Main Menu Help tab
SCGCQ01359020 - Add new card support in HII
SCGCQ01325348 - With secured foreign SED, it is asking you to enter the Passphrase/password.
SCGCQ01291052 - User must be warned when they create a VD across the front backplane and enclosures behind the switch
SCGCQ01376269 - Internal bpis showing up as an encl which causes HII to show the enumeration incorrectly - implement new MR API
SCGCQ01345378 - MR7 PNP additions
SCGCQ01350528 - Select RAID level using QID under suppressif TRUE and then same primtiive generated at runtime
SCGCQ01321222 - HEFU: Sort the connector names, when the names are not in Port 0 -3 format
SCGCQ01344341 - Incorrect Drive Group numbering in "Create Virtual Drive" menu
SCGCQ01351616 - Change the logic for reentering to main entry point in UEFI Driver
SCGCQ01385162 - For SuperCap, HII has the primitive 'Remaining Capacity' which is different compared to other host utilites
SCGCQ01400115 - The physical drive operation % increase in progress is not getting updated
SCGCQ01321208 - When user unloads UEFI Driver nullify pHiiHandShakeProtocol and ask platform to free HII (memory and image handle)
SCGCQ01333899 - Inappropriate message shown when the Reconstruction is initiated again while the previous reconstruction is in progress.
SCGCQ01384314 - With pinned cache generated, HII is auto launched during system Boot when BIOS Mode is set to Ignore Errors.
SCGCQ01321189 - Foreign configuration page seen after changing profile to NVMe.
SCGCQ01321203 - Reset Type and customer messaging for system resets initiated by controller OpROM
SCGCQ01389129 - In the 'Manage SAS Storage Link Speed' form, not able to move the cursor to the next entry.
SCGCQ01407030 - Check All is not working in Assign Dedicated HotSpare form
SCGCQ01334156 - HEFU: Don't check the return value for the function to get connector index and sorted connnector index
SCGCQ01321185 - HII shows wrong Temperature value when Sensor status is "Not Installed"
SCGCQ01334144 - Not able to select check box in some forms
SCGCQ01386798 - Not able to disable JBOD mode when there is file system/operating system present on the controller configuration.
SCGCQ01321210 - HEFU - Sort the disk based on connector name, slot and position
SCGCQ01301650 - Cursor below text and in center of line on the system reset request screen.
SCGCQ01309119 - Debug print shown on the console from the UEFI Driver error path.
SCGCQ01348104 - Click on "OK" button after completing any operation doesn't have any effect in the screen
SCGCQ01349428 - Firmware Management Protocol - Firmware update fails with inappropriate message when trying to update an unsigned
component

BIOS Changes:

SCGCQ01402877 - Legacy BIOS: JBOD Mode – SAS/SATA Large Topology Support
SCGCQ01424581 - System stops at post in legacy mode boot in the multi controllers configuration where-in one of the controller is in fault state
SCGCQ01292708 - Drive ID shown in BIOS POST is more than 1000+, even thought the total drives is only about 160
SCGCQ01379327 - System reset is initiated twice in BIOS
SCGCQ01321554 - Reset Type and customer messaging for system resets initiated by controller optrom

Boot Block Changes:

SCGCQ01357917 - Boot Block Accesses PCI_LINK_CONFIG while PCE Core is Reset

Package Details:

- Firmware Package: 50.5.2-1326 (MR 7.5p2)
- Firmware 5.050.00-1367
- ROMENV 1.12
- BootBlock 7.02.00.00-0017
- NVDATA 5.0500.04-0004
- UEFI_Driver v0x07050400 (SIGNED)
- Hii v07.05.06.00 (SIGNED)
- FCODE 4.17.08.00
- BIOS 7.05.02.0
- SBR: 5.0500.01-0334

UEFI shell instructions for updating RAID Firmware:

- Download and extract all files to a USB flash drive.
- Boot the target system to EFI shell.
- Change directory to the local drive and directory containing the flash update files and the firmware image file.
- Type the name of the .nsh file matching the controller to update (e.g. "RMSP3HD080E.nsh" and press <Enter> to execute the command
- The storcli command line in the .nsh command will default to the first logical RAID contoller ("/c0"). If this there are multiple controllers, the value of controller parameter ("/Cx") will need to be modified to match the specific controller intended for update.
- Wait for the flash to complete. Do NOT reboot the system during the update.
- You can also use RAID Web Console 3 or OS version of StorCLI to update the RAID firmware. For more detail, please refer to the Intel RAID Software User's Guide.

Attention!

- Intel recommends to loading Factory Default setting after the firmware upgrade which will not affect data on any existing array.
- Reboot the system and login to the RAID BIOS Console.
- Select the controller and select 'Adapter Properties'->'Next'
- Set the 'Set Factory Defaults' setting to 'Yes' and submit the change.
- Reboot the system (the default settings are applied).
- Re-configure to the desired settings in RAID Web Console3.

Firmware downgrade notice

- Intel does not recommend to downgrade the factory installed firmware on your RAID module or controller, it has important enhancements and bug fixes you may lose when going to a previous version.
- If you need to install an older firmware version, please contact Intel for instructions on how to perform this action.

About Firmware Updates:

Applying a newer firmware version than the one already installed on your unit can bring various enhancements, include workarounds for diverse problems encountered by the device, and improve or add newly developed features.

On the other hand, downgrading the firmware version can recover the device's functionality in the event of a software update either turning up faulty or causing the unit's overall performance to drop. However, bear in mind that applying an older firmware isn't recommended and might not always be possible.

When it comes to the update steps, due to the large variety of devices and numerous ways for installing a new firmware, it is recommended that you carefully read and understand the upgrade steps, and consider applying a different firmware only when you have familiarized yourself with the update method.

As the installation process is most of the times quite risky, this step should be taken by users that have the ability to successfully complete the update; regular users may initiate it at their own risk. Moreover, it's best that this task be performed in a steady power environment such as the one ensured by a UPS unit.

Therefore, if you consider applying this release, hit the download button, take into account all the aforementioned aspects, and update the device's firmware. Also make sure you constantly check with our website to ensure that you don't miss a single new release.

Intel HNS2600BPQ24 RAID Firmware Intel HNS2600BPQ24 Compute Module Firmware Intel RMSP3LD060 RAID Controller Firmware HNS2600BPQ24 RAID Firmware Intel Compute Module

  CATEGORY:
Firmware
  COMPATIBLE WITH:
OS Independent
  file size:
20.1 MB
  filename: