Grandstream GXW4008 IP Analog Gateway Firmware 1.0.11.3 Beta
Fixes:
- Fixed device trapped into reboot loop under certain conditions
- Fixed retrieving the empty upgrade server path via IVR caused device crash
- Fixed issue with upgrading from 1.0.9.x to 1.0.10.x when “Check New Firmware only when F/W pre/suffix changes” is checked
- Fixed Bridge mode performs DNS relay
- Fixed device sends Loop Current Disconnect for 4xx SIP responses
- Fixed HT503 FXO port cannot detect PSTN plugin
- Fixed HT503 FXS port analog phone dial *00 access to FXO port, analog phone hears dial tone and call waiting tone
- Fixed BroadSoft interop: DUT cannot switch between two lines after receiving server NOTIFY
- Fixed device have Dial tone after Current Disconnect instead of silence
- Fixed during call waiting, some abnormal operation causes some abnormal occurrence
- Fixed after upgrade the base image device get into waiting for upgrade to finish status
- Fixed if caller is not in transfer or hold or waiting status, Current Disconnect should able to work when caller's call setup failed
- Fixed SIP registration interval is not correct. Stopped failover processing if the initial registration try has not been done.
Enhancements:
- Added TR-069 support of moving FXS/Line from one profile to another. New gs_cpe version 1.0.1.42.
- Added support for SHA-256
- Added web UI Option "Add Auth Header On Initial REGISTER" under FXS port page (P value 2359/2459/2559/2659). If set to "yes", include authorization header in the Register request.
- Added a new option, when using DID to call, the From header is DID number. Added option "Use Request Routing ID in SIP Header" in web UI (P value 4891/4892/4893/4894). If enabled, the (SIP) User ID in the From header of an outgoing INVITE is replaced with the Request Routing User ID.
- Added option to remove PPI & Privacy Header. Added “Use Privacy Header” (P value 2338/2438/2538/2638) and “Use P-Prefer-Identity Header” (P value 2339/2439/2539/2639) in web UI.
- CATEGORY:
- VoIP
- COMPATIBLE WITH:
- OS Independent
- file size:
- 3.5 MB
- filename:
- Release_GXW4008_1.0.11.3.zip
- Newer! Grandstream GXW4008 IP Analog Gateway Firmware 1.0.15.52016-08-05
- Newer! Grandstream GXW4008 IP Analog Gateway Firmware 1.0.14.1002016-01-10
- Newer! Grandstream GXW4008 IP Analog Gateway Firmware 1.0.14.100 Beta2015-12-16
- Newer! Grandstream GXW4008 IP Analog Gateway Firmware 1.0.4.100 Beta2015-12-09
- Newer! Grandstream GXW4008 IP Analog Gateway Firmware 1.0.14.12015-05-06
- Newer! Grandstream GXW4008 IP Analog Gateway Firmware 1.0.14.1 Beta2015-04-16
- Newer! Grandstream GXW4008 IP Analog Gateway Firmware 1.0.13.32015-03-27
- Newer! Grandstream GXW4008 IP Analog Gateway Firmware 1.0.13.3 Beta2015-03-12
- Newer! Grandstream GXW4008 IP Analog Gateway Firmware 1.0.12.82015-02-19
- Grandstream GXW4008 IP Analog Gateway Firmware 1.0.11.3 Beta2014-02-17