Initiator should set DataTransferLength in the SCSI Request Block to number of bytes transferred when the target returns CHECK_CONDITION and sets ILI bit in the sense data Initiator hangs while processing asynchronous logout message Initiator sometimes loses the device even though the corresponding iSCSI session is still active. Under heavy load Initiator sometimes sends an untagged request while another request was still pending on the device Fixed invalid data sequence while processing RTT request Registry entry for LinkDown timeout - added a configurable timeout value for tracking link down. The default timeout is 15 seconds. When the link goes down while requests are in progress, initiator will wait for this time out period and then retry the requests. If the link is still down, the requests will be failed This timeout is used only if Multi-Path software is installed. Otherwise, MaxRequestHoldTime is used. The behavior of MaxRequestHoldTime is same as in 1.05 release Added a new parameter to HwFindAdapter routine - Device object below iSCSIadapter FDO is passed as an arguement for HwFindAdapter routine Do not log an event if the connection to the target is lost before async logout response is received iSCSI discovery service will pass the IP Address of the local NIC if the user selects an IP Address through iSCSI GUI Do not log Event 7 and 27 if the iSCSI session is processing async logout
|
|